Sequential Array Scanning

SSC-T800 Series

  • Fine object detection with Sequential Array Scanning
  • With a robust metal case!
  • Five kinds of beam intervals, which you can select according to use!
    • Small objects and flat tape-like objects detected
    • Convenient simplified wiring requiring no clock (synchronization) line
    • Compact and flat (14.5mm)
    • Water resistance compliant with IP 67
Contact us about this series

SSC-T800 Series

Model Detecting width Optical axis interval Detection object Output mode Protective structure  
SSC-T801 50mm 5.55mm Opaque φ6mm or more NPN IP67
Contact
SSC-T801PN 50mm 5.55mm Opaque φ6mm or more PNP IP67
Contact
SSC-T802 50mm 5.55mm Opaque φ8mm or more NPN IP67
Contact
SSC-T802PN 50mm 5.55mm Opaque φ8mm or more PNP IP67
Contact
SSC-T804 50mm 12.5mm Opaque φ15mm or more NPN IP67
Contact
SSC-T804PN 50mm 12.5mm Opaque φ15mm or more PNP IP67
Contact
SSC-T805 50mm 12.5mm Opaque φ12.5mm or more NPN IP67
Contact
SSC-T805PN 50mm 12.5mm Opaque φ12.5mm or more PNP IP67
Contact
SSC-T810 100mm 11mm Opaque φ11mm or more NPN IP67
Contact
SSC-T810PN 100mm 11mm Opaque φ11mm or more PNP IP67
Contact
SSC-T815 100mm 20mm Opaque φ20mm or more NPN IP67
Contact
SSC-T815PN 100mm 20mm Opaque φ20mm or more PNP IP67
Contact
SSC-T830 100mm 11mm Opaque φ13mm or more NPN IP67
Contact
SSC-T830PN 100mm 11mm Opaque φ13mm or more PNP IP67
Contact
SSC-T835 100mm 20mm Opaque φ22mm or more NPN IP67
Contact
SSC-T835PN 100mm 20mm Opaque φ22mm or more PNP IP67
Contact
SSC-T850 150mm 16.6mm Opaque φ17mm or more NPN IP67
Contact
SSC-T850PN 150mm 16.6mm Opaque φ17mm or more PNP IP67
Contact

More Info

Sequential Array Scanning

SSC-T800 makes a sequential scan of a two dimensional array formed by each transmitter and the whole set of corresponding receivers.
This method of scanning creates a high-density detection net between the transmitter and the receiver. Thin pipe, tape or name cards that pass through conventional light curtains can be reliably detected.

The figure on the right shows a model with six light axes. The number of light axes depends on the model.

SSC-T801

When installing the main unit of the sensor, the tightening torque has to be 0.6N m or less.

SSC-T850

When installing the main unit of the sensor, the tightening torque has to be 0.6N m or less.

SSC-T810
SSC-T830

When installing the main unit of the sensor, the tightening torque has to be 0.6N m or less.

SSC-T815
SSC-T835