Ultra thin Slim type of only 13 mm thick and 30 mm wide never affecting work efficiency
High intensity red LED indicator Large operation indicator of high intensity LEDs in series offering superb visibility, may double as work instruction indicator
Objects as small as φ30mm detected
Automatic sensitivity compensation feature
Anti Interference feature Allowing adjacent mounting of 2 units for wider range of applications
Adjacent or face to face installation of two pairs of sensors will not cause interference.
Protective cover
With mounting bracket model ES-BF
With mounting bracket model ES-BL
NPN output
In the condition of load short circuit or overload, the output transistor turns off. Check the load condition before restarting.
PNP output
(*1) Connect the MS line (purple) of the transmitter of either (A) of the two sensors to the ground line (blue), which sets the operation mode of this sensor (Sensor A) to master (M mode).
(*2) Connect the MS line (purple) of the transmitter of the other sensor (B) to the synchronization line (orange/purple) of Sensor A, which sets the operation mode of Sensor B to slave (S mode).
(*3) When using different power supplies for the transmitter and the receiver, or for the master and slave sensors, be sure to use the common 0V for each unit.
* When using two sets as a pair, wire so that the operation mode of either of the two will be master and of the other will be slave.