FD-A300P Series
- Sensitivity adjustment unnecessary: Auto sensing
- One sensor covers a wide range of temperatures from low to high
Model | Output type | Control output | Protective structure | |
---|---|---|---|---|
FD-A300P | Mini power relay output | Light ON/Dark ON Rating: 1c 5A 250VAC Response time: 15ms |
IP66 | |
FD-A300PC | Solid state output | Light ON/Dark ON Rating: 0.5A 250VAC/DC Response time: 5ms |
IP66 | |
FD-A300PH | Signal relay output | Light ON/Dark ON Rating: 1c 0.5A 48VDC Response time: 5ms |
IP66 | |
FD-A300PM | Photo MOS relay output | Light ON/Dark ON Rating: 0.1A 100VAC/DC Response time: 4ms |
IP66 |
FD-A300P is a series of optical fiber type hot metal detection photo sensor (HMD) that directly detect infrared energy emitted from heated material (steel products, etc.).
Equipped with a controller that employs an 8-bit microcomputer, this intelligent hot metal detection sensor integrates various functions.
Guidelines are given below for the temperature of a detection object larger than the detecting field of view with optical head (OHA) and fiber optic cable (FG2) used for detection.
Low temperature range | 350 - 800C |
---|---|
High temperature range | 490 - 1300C |
The minimum temperature depends on the length of the fiber optic cable used or the detecting field of view of the optical head.
Temperatures shown in this table are for heated material larger than the field of view. If the material is smaller than the field of view, the lowest detectable temperature is increased. The guidelines are for the minimum temperatures of detection objects with margins of about four times as much as the inherent performance. For detailed data, see “Minimum Detectable Object and Lowest Detectable Temperature.”
Low temperature range | High temperature range | |||||
---|---|---|---|---|---|---|
Fiber length | Optical head | Optical head | ||||
Standard view model OHA |
Narrow view model OHAN/OHAN10 |
Wide view model OHW1/OHW2 |
Standard view model OHA |
Narrow view model OHAN/OHAN10 |
Wide view model OHW1/OHW2 |
|
2m | 350C | 480C | 415C | 490C | 685C | 590C |
3m | 365C | 500C | 430C | 510C | 705C | 610C |
4m | 375C | 515C | 445C | 525C | 720C | 625C |
5m | 385C | 530C | 450C | 540C | 735C | 635C |
7m | 400C | 550C | 475C | 560C | 760C | 660C |
10m | 445C | 600C | 520C | 610C | 850C | 725C |
15m | 480C | 640C | 555C | 655C | 920C | 775C |
20m | 500C | 665C | 580C | 680C | 960C | 800C |
30m | 530C | 705C | 610C | 720C | 1030C | 850C |
When connecting an inductive load such as relay, be sure to use diode, surge absorber, etc. to protect output transistors from counter electromotive force.