North America
TAKEX America Inc.

151 San Zeno Way, Sunnyvale
CA 94086, USA

(877) 371-2727
Latest news
ATX West 2019
We will be exhibiting at ATX West, Booth 4389 February 5-7, 2019 - Anaheim Convention Center, CA. ATX West is North America's biggest annual automati ...more
Automate 2019
TAKEX America, Inc. will be exhibiting at Automate, April 8-11 2019 at McCormick Place, Chicago IL - booth #8649. Automation is helping companies in ...more
(877) 371-2727
TAKEX America Inc.
151 San Zeno Way, Sunnyvale CA 94086, USA
Anti-Crawl / PXB-100ATC-KH

PXB-100ATC-KH

Description

PXB-100ATC-KH
up to 330ft outdoor

The PXB-100ATC-KH photoelectric beam sensor is designed specifically for use in our TA Series Beam Towers for high-risk applications where detection of all intrusion attempts is critical. Sophisticated dual response output systems have been designed to distinguish and allocate specific alarm responses based on the size and speed of target objects moving through the detection area, and a unique synchronized timing system ensures unrivalled detection performance and versatility.

Features


  • independent control of upper and lower beams
  • specifically designed for use in TA series Tower Enclosures
  • double coated electronics for demanding environments
  • choose between synchro-quad and anti-crawl operation
  • dual outputs for crawl attempt and full beam break
  • sync wire allows unlimited stacking without crosstalk
  • 4 selectable beam channels
  • increased beam separation minimises nuisance alarms
  • vivid internal colour aids beam alignment procedure
  • lightning and surge protection up to 15kV

  
  

Details

  • Specifications
  • Downloads

Model PXB-100ATC-KH
Detection system Near infrared beam interruption system
(4 beams simultaneous interruption or upper/lower 2 beams interruption)
Infrared beam Double modulation pulsed beam by LED
Protection distance Outdoor 100m (330ft) or less
Indoor 200m (660ft) or less
Response time AT output : upper and lower 2 beams simultaneous interruption 0.05sec.  0.1/0.2/0.3/0.5 sec. by either level interruption
HF output : 0.05 sec by upper/lower 2 level simultaneous interruption
Supply voltage 12V to 30VDC (Non-polarity)
Current consumption Transmitter : 27mA / Receiver : 48mA
Alarm output Dry contact relay output : N/C or N/O selectable
Contact action : Interruption time (min. 2 sec)
Contact capacity : 30V (AC/DC) 1A (resistive load)
Protective resistor
Environmental output Dry contact relay output : N/C or N/O selectable
Action : activated when weather condition worsens (min. 5 sec)
Contact capacity : AC/DC30V 1A (resistive load)
Protective resistor
Alarm LED Red LED (Receiver) ON : when an alarm is initiated
Attenuation LED Red LED (Receiver) ON : when beam is attenuated
Ambient temperature range -35°C to +66°C (-31°F to +151°F)
Beam Adjustment
Horizontal : ±90° / Vertical : ±20°
Functions Modulated beam frequency selection
Tone indicator
Environmental module
Beam power selection
Transmitting power adjustment
Programmed AGC
Synchro timing selection
Auto-gain lock function
Monitor jack
Tamper
Response time adjustment
Alarm output selection
Environment output selection
Upper / Lower beam switch
Wireless Alignmnet Checker connecting function
Mounting positions Inside TA Series Beam Towers
Wiring Terminals
Weight Transmitter : 12.6oz
Receiver : 15.8oz

Instruction Manual